PRODUCT

Cementitious Waterproofing System

STEP 3

CMW-3

  • Application

    Cementitious Waterproofing (2K)

  • Volume/Color

    Packing (1 set) : 5kg waterproofing powder + 4L waterproofing liquid

  • Coverage Area

    Approx. 5–8㎡ for 2–3 coats
    (3 coats on horizontal surfaces, 2 coats on vertical or sloped surfaces)
    (Coverage may vary with substrate and application)

  • Features

    Highly Adhesive, Breathable Waterproof Coating · Damp-surface compatible — no drying delay · Multi-purpose waterproofing material

Product Details

Cementitious Waterproofing (2K)

CMW-3

  1. • Highly Adhesive, Breathable Waterproof Coating
  2. • Damp-surface compatible — no drying delay
  3. • Multi-purpose waterproofing material



Benefits

  • Two-component (powder + liquid), no additional water, cement, or sand
  • Easy application with a brush or roller 
  • Breathable coating — allows vapor diffusion and prevents blistering or delamination
  • Strong adhesion to existing polyurethane


Competitor'sCHILMAN


Recommended Use

  • Rooftops, balconies, bathrooms, exposed concrete, and mortar surfaces
  • Suitable for both new construction and repair projects



Packaging &Coverage

  • Packaging : 5kg waterproofing powder + 4L waterproofing liquid
  • Coverage   : Approx. 5–8㎡ for 2–3 coats
      (3 coats on horizontal surfaces, 2 coats on vertical or sloped surfaces)
      (Coverage may vary with substrate and application)


Lack of breatha  bility may cause substrate corrosion and delamination


Application Steps

  • Step 1 : Substrate Preparation
    Refer to page 5 " Pre-Application Checklist for Waterproofing"
    If the substrate is weak or cracked, apply CMW-1 or CMW-2 first, as needed.   

  • Step 2 : Product Preparation & Mixing
    Stir before use : do not dilute with water.
  • Step 3 : Application
    Apply evenly with a brush, roller.
  • Step 4 : Drying Time
    Proceed to next step once touch-dry (approx. 10 minutes to 2 hours)






Notes

  • If ambient temperature exceeds 28°C, lightly dampen the surface before application
  • Internal moisture is acceptable, but the surface must be visibly dry
    Refer to page 5 “Application, Storage &Safety Instructions.”

Full Application Process 


Back to List